DG1 - Terminal programming
Factory setting
-
Check the time and date on the MDU (handheld device):
“Main Menu” > “MDU Functions” > “MDU Clock” -
Briefly hold the configuration transponder Beam (05) to the terminal.
(LEDs light up steadily: communication mode) -
On the MDU, go to:
“Terminal Functions” > “Configuration” > “Serial Commissioning”, then select the appropriate room designation. -
Hold the MDU close to the terminal and confirm the room with the green checkmark.
-
The data will be transferred to the terminal.
If successful, the display will show “Terminal programmed”. -
Exit communication mode by pressing the top red cross on the MDU.
Already configured (in use)
-
Check the time and date on the MDU (handheld device):
“Main Menu” > “MDU Functions” > “MDU Clock” -
Briefly hold the configuration transponder Beam (05) to the terminal.
(LEDs blink: wait – also known as the four-eyes principle) -
While the LEDs are blinking, hold the privileged transponder to the terminal.
(LEDs light up steadily: communication mode) -
On the MDU, go to:
“Terminal Functions” > “Configuration” > “Serial Commissioning”, then select the appropriate room designation. -
Hold the MDU close to the terminal and confirm the room with the green checkmark.
-
The data will be transferred to the terminal.
If successful, the display will show “Terminal programmed”. -
Exit communication mode by pressing the top red cross on the MDU.
Stand Alone (without software)
-
Perform a full reset according to the manual.
(This will erase all programming and delete cards stored in memory) -
The terminal will flash green (requesting programming card):
Hold the programming card to the terminal. -
The terminal will then flash red (requesting delete card):
Hold the delete card to the terminal.
Then:
-
Hold the programming card to the terminal.
(Terminal flashes green – waiting for user keys) -
Hold the user key(s) to the terminal.
-
Wait until the flashing sequence finishes.